Cobetter SSPS Powder Sintered Filter Cartridges are constructed with stainless steel powder. First shaped with pressure and then sintered under high temperature by applying unique technology and strict production process. Features include high mechanical strength, high temperature resistance, even pore distribution, and cleanable.
Filtration Medium | 304/316 Stainless Steel |
End Cap | 304/316 Stainless Steel |
Double Open-End (DOE) |
Single Open-End(SOE) |
Diameters | 60mm |
Additional Diameter Specifications Available Upon Request
Max. Differential Pressure | 4.0bar |
Max. Operating Temperature | 480°C |
Code | Removal Ratings(μm) | Pore Efficiency% | Initial Differential Pressure(KPa) | Absolute Removal Rating(μm) | Average Air Permeability (L/dm²min) | Flow Rate (m³/h) |
1 | 0.45 | 30-50 | 28 | 5 | 0.12 | 0.16 |
2 | 1.0 | 21 | 10 | 0.97 | 0.23 | |
3 | 5.8 | 5.8 | 17 | 1.6 | 0.31 | |
4 | 5.0 | 3.0 | 30 | 2.27 | 1.28 | |
5 | 10 | 2.6 | 50 | 5.50 | 3.38 | |
6 | 20 | 2.1 | 70 | 10.87 | 5.1 | |
7 | 30 | 2.0 | 90 | 15.10 | 5.8 | |
8 | 50 | 1.9 | 120 | 14.50 | 6.2 | |
9 | 80 | - | - | - | - | - |
10 | 100 | - | - | - | - | - |
11 | 120 | - | - | - | - | - |
Testing Method: Bubble Point Method
Testing Performed According to GB/T5453; Testing DP is 200Pa; Testing Medium is Air Testing Method: Bubble Point Method
Testing Liquid Viscosity is 1CP.S; Filter Tested with 60mm diameter and 300mm length; Testing Pressure is 1.5 bar
Length | Filtration Area |
5 in. (125 mm) | 0.024 m² |
10 in. (300 mm) | 0.047m² |
20 in. (500 mm) | 0.094 m² |
30 in. (750 mm) | 0.141 m² |
40 in. (1000 mm) | 0.188m² |
Length and Other Sizes Are Customizable
Tested Filter Diameter is 65mm
Physical Cleaning Methods: Reverse-Flow by Clean Water; Reverse-Blow by Clear Air and Ultrasonic Wave
Chemical Cleaning Methods: Use Cleaning Agent Such As Diluted Acid, Diluted Alkalis, Oxidizer, and Surfactant
Contamination Materials | General Cleaning Method Procedures |
Decarburization in Pharmaceutical and Chemical Industries | Reverse-blow and reverse-ow used more frequently; ultrasonic wave cleaning used when necessary |
Non -Water Soluble Salts and Oxides in the Pharmaceutical Industry | Soak in 5% Concentration of Nitric Acid Solution |
Original Liquid Filtration | Choose the correct cleaning methods as per the chemical properties of the contamination material; The Ultrasonic Wave Cleaning can be combined to use when necessary |
Chemical Cleaning Methods | Detailed Procedures |
Alkaline Cleaning | Alkaline Cleaning Soak filter in 3-5% Concentration of AR grade NaOH Solution for 30-60 minutes; solution temperature is 40°C. Flush the soaked filter inside, out with DI water or WFI water until the flushed solution turns neutral , and then test its conductivity. Dry with Pure Air 0.4Mpa |
Acid Cleaning | Soak it in the 5% Concentration of Nitric Acid Solution for at least 8 hours; solution temperature is 40°C. Flush the soaked filter inside, out with DI water or WFI water until the flushed solution turns neutral, and then test its conductivity. Dry with Pure Air 0.4Mpa |
Original Liquid Filtration | Clean filter with surfactant caused by contamination with Organic Pollution ( high concentration of Citric Acid recommended for Food and Beverage Applications) |